XXG-2505A Smaller sized Portable X ray Machine with19kg and
40°Radiation
Parameters
Model | XXG-2505A |
Tube | Ceramic |
Output voltage | 150-250 KV |
Focus size | 2.0×2.0 mm |
Radiation angle | 40° |
Penetration | FE 40mm |
Generator size | 270×270×620 mm |
Generator weight | 32kg |
Controller size | 310×210×130 mm |
Controller weight | 7 kg |
Input power | AC 185-245V @50~60Hz |
Cooling | Air
|
Introduction
1. It can still work by applying special design what can avoid the
interference by power grid change.
2. We are using highpower electronic components,such as capacitance
and power module with wide capability to greatly ensure the quality
of the products.
3. Apply the isolation technology of low voltage and high voltage
to ensure the controller working stablely.
4. It has functions of troubleshooting automatically and pressure
indication to guarantee the stability of working.

Distinguishing feature
Adopting micro-computer control and modular structure,with strong
anti-interference ability and high automaticity and reliable
performance.
Parameter setting,working process and trouble indication will be
indicated on the LED lamp.
Independent ageing key is designed for age the machine
conveniently.
Radiating time to cooling time is 1:1.
The controller can notice the type of x-ray generator
automatically.
The water and dust proof color panel and digital sound keyboard are
introduced that exposure parameters are promptly and accurately
selected.
Ensure safety useing the instrument,it is installed with
overvoltage,undervoltage,overcurrent,undercurrent and
overtemperature protection device.
Adopting the wider range of kv value, and solve the difficulty
problem of short radiographic range.
Exposure delay function——the delay time can be set less than 10
minutes to keep the operator safe from working place.

Composition and Application
x ray flaw detector consists of three parts,controller, generator
and connection cable .
X Ray flaw detector plays important parts in carrying on
nondestructive examination for nonmetallic, light metal, casting,
various alloys and pressure vessels etc, mainly detecting weld
defects ,such as crack, blowhole, entrapped slag, incomplete fusion
,blowhole,bubble etc ,also using for shipbuilding ,airplane and
national defense etc industry fiel.
Matters needing attention
(1) The temperature of the container X ray generator, with the use
of time may be rising, handling equipment on cameras, please wear
gloves handling, and must be handled with care.
(2) In handling X mobile X-ray machine, if severe vibration or
shock, can make X ray tube fragmentation or filament deformation or
high voltage coil move, resulting in equipment is not working
properly or damaged.
(3) The X ray generator in the car, forklift, must stand (fan end
in), while below the mat cushion, if must be sideways when carrying
rings at both ends to pad the damping material to prevent shock.